URWERK EMC "Time Hunter"
www.watch4umen.com.URWERK EMC "Time Hunter" debut at SIHH 2016 Advanced Watch Fair, is a 100% mechanical watch, with electronic enhanceability. It is divided into two batches of 15 pieces, namely natural titanium / steel, one with military green ceramic coated titanium / steel shell.
EMC "Time Hunter" has a highly clear time display, central time and minutes expressed with high contrast black hand enhanced with bright white super LumiNova. The revolving disc showing the number of seconds at 1 o'clock is visually balanced by its enantiose power reserve indicator at 7 o'clock. Super LumiNova also ensures nightly high clarity as it emits blue and white.
10 o'clock the upper left corner of the dial shows two EMC electronic instructions: timing accuracy of +/- 15 seconds per day, the balance range. The watch uses an integrated circuit board (EMC "brains"), one of the two spring sleeves near the top, as well as the balance wheel on the top and the winding handle side of the optical sensor.
EMC "Time Hunter" uses the same technology used in the EMC watch introduced in 2013. The most advanced EMC Caliber helps electronic components, enabling the wearer to monitor the health (amplitude) of the watch and its accuracy. Worn on the wrist.best cheap Hublot Ferrari Watches
What are the benefits of EMC Time Hunter for the wearer?
When the watch is adjusted (precisely tested and adjusted) by the watchmaker before sale, it is usually placed on a continuously rotating arm in a room where the temperature is stable. The rotating arm ensures that the watch takes considerable time in all positions. But the timing of the mechanical watch in each position and the temperature changes slightly change. So in the real world of watch watches, how long each position (on average) will depend on the activities of the wearer: work, leisure, and the time of day's actual wear. Two different people wearing the same watch a week will find its accuracy is different, because the watch will be in a week in different activities through different positions.
EMC allows the wearer to record the number of seconds that the watch has received or lost in a week (or month) to adjust the accuracy and then use the EMC functional test accuracy to confirm that the adjustment is correct. This concept of interactivity allows EMC to act as precisely as possible for a particular wearer's lifestyle, even with any change.
How to run
The folding crank handle is first wound to produce the power of the EMC indication, - no battery, and then stored in the supercapacitor. After winding, the hand indicates δ (in progress) or P (power is insufficient). Then, the EMC hand will first indicate the accuracy of the movement as +/- 15 seconds per day for a few seconds, then the balance of the range, which is a good indicator of athletic health if needed. In addition to these two indications, the LEDs on the precision display between -5 and -15 seconds will light green when all are good, and if one or two EMC indications fall on acceptable parameters, the red Will light up.luxury cheap Urwerk UR-202 watches
The folding crank handle is first wound to produce the power of the EMC indication, - no battery, and then stored in the supercapacitor. After winding, the hand indicates δ (in progress) or P (power is insufficient). Then, the EMC hand will first indicate the accuracy of the movement as +/- 15 seconds per day for a few seconds, then the balance of the range, which is a good indicator of athletic health if needed. In addition to these two indications, the LEDs on the precision display between -5 and -15 seconds will light green when all are good, and if one or two EMC indications fall on acceptable parameters, the red Will light up.luxury cheap Urwerk UR-202 watches
You can then adjust the accuracy of the movement faster or more slowly by rotating the screws on the back of the watch. This allows the user to adjust the time to fit their lifestyle.
What is the magnitude, why is the EMC measurement range?
Although the concept of precision (such as the speed of the watch running every day or speed in a few seconds) is quite easy to understand, but the balance is not obvious. Grandfather bell accuracy by the pendulum swing swing adjustment, and the accuracy of the watch from the front and rear swing balance adjustment. The "amplitude" is the degree to which the pendulum or balance wheel moves in each oscillation.
Although in theory, the pendulum and the balance wheel should be synchronized in all amplitudes, that is, each oscillation should be exactly the same time, whether it is swinging a short or longer distance, in fact most of the watch movement The balance should be 220 ° and 280 ° to achieve maximum efficiency. Since the tiny balance wheel has a relatively low quality and so rapidly oscillates (four times per second), the slight degradation in the lubricating oil of the balance (shaft) shows a lower amplitude. Therefore, the balance is the movement of "healthy" or need to serve a good indicator. The balance is almost every movement of the mechanical watch "heart". As with our own heart, the intensity of its beat (amplitude) and the regularity of its rhythm (precision) are good indicators of health.
What's on the back?
Before we get a closer look at the movement, the two things that need to be noticed behind EMC are the timing of the fine adjustment screw at the top, used to fine-tune the movement of the movement and the bottom of the fiddler between the clever pop-up crown. By returning to the movement through the display, we see the lid on the balance cover for measuring the balance of the oscillation accuracy of the optical element, a fine line through the right side of the grid visible electronic cable. Vertical stacking double barrel is also prominent in the electronic circuit board.
The bold idea of incorporating Witschi-type measuring instruments into mechanical watches has become a true pursuit of URWERK.nice cheap Richard Mille RM 011 Titanium Strap watch
At its core, EMC has three goals: to show how external parameters (position changes, temperature and pressure) affect movement time; to allow the wearer to adjust the time; and to facilitate interaction between the watch and its owner.
EMC has always been a sophisticated mechanical watch, the internal action by the Zurich URWERK studio concept, development and production, and by the Geneva URWERK calibration. The movement meets the most stringent quality control, and its timing performance is tested in five locations over a 30-day period to ensure that it meets the highest standards of precision watches.
EMC's movement is equipped with the following features:
- Customized balance wheels made by ARCW, which have long been expected by URWERK for its non-magnetic and corrosion resistance. At first glance, this particular development of the balance of originality is amazing. The complete linear form is the result of careful calculation to optimize the data from the optical sensor, maximizing aerodynamic efficiency and minimizing amplitude loss.
- Customized balance wheels made by ARCW, which have long been expected by URWERK for its non-magnetic and corrosion resistance. At first glance, this particular development of the balance of originality is amazing. The complete linear form is the result of careful calculation to optimize the data from the optical sensor, maximizing aerodynamic efficiency and minimizing amplitude loss.
- Power is provided by two large mainspring mounted vertically on a single shaft. These provide up to 80 hours of power reserve, which is conducive to stable linear timing performance.
- The timing adjustment screw can be carried out on the back of the watch and allows the owner to adjust the balance length by adjusting the effective length of the balance spring by turning the simple screw to fine adjust the balance rate adjuster.
The innovative EMC timing rate monitoring unit has been developed to include the following:
- The optical sensor on the balance wheel captures the exact oscillation rate of the 4 Hz / 28,800 vph regulator in 3 seconds. The sensor consists of a transmitter and a receiver located on both sides of the balance and is manually triggered by pressing the button on the left side of the housing.
- A 16,000,000 Hz electronic oscillator provides EMC reference timing rates. Compare the balance performance of EMC (4 Hz) with the lightning oscillator to obtain the most accurate measurement results.
- Artificial intelligence (computer) Determines the difference between the timing of the motion and the timing of the reference oscillator. The difference between the two values per second is expressed as the second gain or loss per day for the timing rate. Each half of the vibration once only 0.0000014 seconds change can change one second per day.
- manual winding generator (generator). EMC's monitoring units (optical sensors and computers) are powered by micro-generators manufactured by Swiss company Maxon,sale cheap Meccaniche Veloci watches
No comments: